HomeFlame Safe ProductsFire Retardant WoodTestingAbout Us- ServicesContact UsVideos
Fire Poly FP100Fire Poly FP75EFire Poly FP75IFire Poly FP50Fire Poly FPCCWood SafeShingle Safe
Thatch SafeFabricSafePaper SafeTree SafeFlame Safe Logos & ImagesFlame Safe Logos & Images

FLAME SAFE
Hotline: 1-800-333-9197 8am-5pm (CST) Ph: 817-740-9197 
After Hours: 817-658-9197 email: fireprod@aol.com 
  On your mobile click here to dial  
Dallas, Fort Worth, Austin, Houston, San Antonio, El Paso, Dallas, Amarillo, Abilene, Lubbock, Corpus Christi, North, Dallas, Dallas county, Midland, Odessa, Plano, Frisco, Wichita Falls, East Dallas, and moreallas, Fort Worth, Austin, Houston, San Antonio, El Paso, Dallas, Amarillo, Abilene, Lubbock, Corpus Christi, North, Dallas, Dallas county, Midland, Odessa, Plano, Frisco, Wichita Falls, East Dallas, and more
TEST
MATERIAL 
TESTED
RESULTS
FLAME SAFE FIRE POLY FPCC TECHNICAL DATA

 FIRE RETARDANT COATING 
PRODUCT DESCRIPTION: Aqueous Based Resin​

PRODUCT ANALYSIS

Total Solids 46%        PH: 2.5-2.8
Weight per gallon 11.1 lbs
Specific gravity: 1.33
Flash point:  non-flammable
Color:  Water clear at 78°F.- slight haze at 50°F.and lower
Volatibility:  Non-volatile
Solvents:Water (contains no petroleum or derivatives of petroleum.)
Bacterial: Good Resistance 
Corrosive:Mildly
Impact resistance: Good
Moisture Absorption: Slight
Toxicity:  None(when dry)
Incompatibility: Strong oxidizers, alkalis or acids (materials to avoid)

Fire Endurance and Hydrostateic Evaluation Based on International Maritime Organization Resolution (MQ) Resolution A.753(18); Appendix 2 and ASTM F1173-95 Section A5 Wet Condition Classification of Water Filled Plastic Pipe
Conley epoxy 29, 6-in.FLGXFLG Spool pipe coated with Flame Safe Chemical Corporation's Fire Poly FPCC
PASSED
FIRE ENDURANCE                 PASSED

Number of fire retardant coats: 3
Rate per coat (sq ft gal): 1050
RECOMMENDED USE: Pressurized plastic and composite piping systems

FLAME SAFE FIRE POLY FPCC:  Specially formulated for use on plastic pipe

ENVIRONMENTAL REGULATION:
This product complies will U. S. Federal Regulations concerning the use of lead in paint, and hydrocarbon emissions.
QUICK REFERENCE FOR APPLYING  FIRE POLY FPCC
MATERIAL
APPLICATION
COVERAGE
Plastic Pipe




Polystyrene foam
Styrofoam
Be sure surface is clean and dry before treating.

Apply with sprayer head held at 8 to 12 inches from surface.

Be sure to allow drying between each coat.

Apply three (3) coats at 1050 sq. ft. Per coat with the final coverage rate of 350 sq. ft. per gallon
INTERIOR / EXTERIOR:

All surfaces to be treated must be clean and dry. Fire Poly FPCC is water based, clear liquid that becomes insoluble when dry. If over-coating is intended, Fire Poly FPCC is an excellent primer for use under or over latex paints.  DO NOT DILUTE OR MIX FIRE POLY FPCC WITH ANY OTHER PRODUCTS. Avoid wasteful runs and dripping. It should be noted that unlike some products, materials treated with Fire Poly FPCC require no special cutting tools or special fasteners. Contact parts of any equipment should be stainless steel or plastic to prevent chemical reaction and breakdown. Storage may be done in polyethylene containers.
CAUTION:

Product must not freeze. It MUST NOT be thinned or diluted.

OVERSPRAY:

The overspray will not harm plants or animals. Spills can be flushed with water rag wetted with bleach and water mix will clean up spotting.

CLEAN UP PROCEDURE:

Airless Equipment:
1. Run clear water through the system until saturant is flushed out. When minor sudsing on surface stops, the system is flushed.
2. Run bleach and water mix (1 part to 4 parts) through the spray system as solvent for cleaning and to remove any residue.
3. Repeat Step 1 if any foaming occurs in Step 2.
4. Lubricate system as specified by equipment manufacturer to combat rusting or corrosion.

If two or more jobs are planned in the same day, the sprayer can be kept clean by running water through the system between jobs.


SAFETY FIRST:

It is a good practice to wear a respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask does not provide protection against vapors.

If eye contact occurs, flood with water for fifteen (15) minutes and call a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY. 

FIRE POLY FPCC FIRE RETARDANT

NFPA 701 - STYROFOAM
Apply three (3) coats at 600 sq. ft. per gallon with the final coverage rate of 200 sq. ft. per gallon