FIRE POLY FP100 FIRE RETARDANT​ COATING

ASTM E84, Class A;  UL723, Type 1,  NFPA 255;
UBC 8-1; ASTM D2898
SURFACE BURNING CHARACTERISTICS
 OF APPLIED COATING
​Flame spread: <10
Smoke developed: <125
Number of preliminary coats: None
Rate per coat (ft2/gal)--
Number of fire retardant coats: 1-3
Rate per coat (ft2/gal): 200-600
Number of overcoats: None
Mil thickness4
Flash point of liquid coating:
Fire retarding coating - closed cup,no flash
HomeFlame Safe ProductsFire Retardant WoodTestingAbout Us- ServicesContact UsVideos
Fire Poly FP100Fire Poly FP75EFire Poly FP75IFire Poly FP50Fire Poly FPCCWood SafeShingle Safe
Thatch SafeFabricSafePaper SafeTree SafeFlame Safe Logos & ImagesFlame Safe Logos & Images

FLAME SAFE
Hotline: 1-800-333-9197 8am-5pm (CST) Ph: 817-740-9197 
After Hours: 817-658-9197 email: fireprod@aol.com 
FLAMESAFE FIRE POLY100 TECHNICAL DATA

 FIRE POLY (Interior/Exterior Class A Rating)
RECOMMENDED USE: Interior/Exterior Class A Rating (Flame spread less than 20)

FLAME SAFE FIRE POLY 100 iis a high intumescent fire retardant coating. It can be used on any type of wood, porous, or non-porous materials, such as:

Yellow pine - Redwood  - Cedar  - Douglas Fir - OSB - Maple - Oak -  Poplar  - Walnut - I-Joists - Cyprus - Mahogany - TeakThatching - Trusses - Bamboo  - Koa -  Ponderosa Pine  - Plywood  - Rim Board

ENVIRONMENTAL REGULATION:
This product complies with U. S. Federal Regulations concerning the use of lead in paint and hydrocarbon emissions.
CAUTION:
Product must not freeze. It must not be thinned or diluted.

OVERSPRAY:
The overspray will not harm plants or animals. Spills can be flushed with water. A rag wetted with bleach and water mix will clean up spotting.

CLEAN UP PROCEDURE:
Airless Equipment.
1. Run clear water through the system until coating is flushed out. When minor sudsing on surface stops, the system is flushed.
2. Run bleach and water mix (1 part to 4 parts) through system as solvent for cleaning any residue.
3. Repeat Step 1 if any foaming occurs in Step 2.
4. Lubricate system as specified by equipment manufacturer to combat rusting.

If two or more applications are planned in the same day, the sprayer can be kept clean by running water through the system between applications.

Brushes/Rollers.
1. Clean immediately after use.
2. Wash thoroughly with bleach and water mix (1 part to 4 parts).

SAFETY FIRST
Use approved safety devices (ropes, belts, ridge hooks, ladder, etc.) When working on steep or high areas. Take EXTREME CARE not to step on wet treated area. Surface may be slick until dry.
It is good practice to wear respirator or mask and protect hands with rubber gloves when spraying any coating or chemical. When engineered air control is not feasible, use properly maintained and properly fitted NIOSH approved respirator for solvent vapors. A dusk mask noes not provide protection against vapors.
If eye contact occurs, flood with water for fifteen (15) minutes and call a physician. KEEP OUT OF REACH OF CHILDREN. DO NOT TAKE INTERNALLY.
PRODUCT DESCRIPTION: Aqueous Based Resin​

PRODUCT ANALYSIS

Total Solids51%
Weight per gallon11.1 lbs
Color:    Water clear at 78°F.- slight haze at 50°F.and lower
Volatibility:  Non-volatile
Solvents:Water (contains no petroleum or derivatives of petroleum.)
Anti-Fungus: Good resistance
Bacterial: Good Resistance 
Linear shrinkage:None
Corrosive:Mildly
Insects, rodents, aspergilli and other types of molds: good resistance
Termites:good resistance
Scrubability:1000 cycles
EXTERIOR / INTERIOR WOODS
All surfaces to be treated must be clean and dry. Fire Poly is water-based, clear liquid that becomes insoluble when dry. On exterior wood Fire Poly can last five years or more, while maintaining a flame spread index of less than 20. In extreme weather conditions it may be necessary to re-coat surfaces every three to five years. It also acts as a preservative, waterproofing agent, ultra violet inhibitor, mold and mildew inhibitor, and it repels insects. If over coating is intended, Fire Poly is an excellent surface primer for use under latex paints, or can be used as a finished coat over water based stains. Finished surfaces will exhibit semi-gloss to gloss finish similar to lacquers or epoxies. DO NOT DILUTE OR MIX FIRE POLY WITH ANY OTHER PRODUCTS.  Contact parts of any equipment should be stainless steel or plastic to prevent chemical reaction and breakdown. Storage may be done in polyethylene containers.
Fire Poly when applied according to the manufacturer’s specifications is the most effective fire retardant coating available.
​​QUICK REFERENCE FOR APPLYING FIRE POLY 100
MATERIAL
APPLICATION
COVERAGE
Exterior/Interior wood  
  Any type of wood
Treat before, during or after construction

Be sure surface is clean 
and dry before treating.

Apply with sprayer head held at 8 to 12 inches from surface.

Apply with brush or roller.

May be necessary to wipe on hardwood surfaces

Treat all surface areas 
where possible.

Do not expose treated area
to moisture for 24 hours.
Apply one (1) coat at the rate of 200 sq. ft. per gallon
Dallas, Fort Worth, Austin, Houston, San Antonio, El Paso, Dallas, Amarillo, Abilene, Lubbock, Corpus Christi, North, Dallas, Dallas county, Midland, Odessa, Wichita Falls, Cleveland,OH, Chicago,IL, Pittsburgh,PA 
Intumescent.fire retardant coating swells as a result of heat exposure or flame